Feature Highlights:
Compare Products
Hide
VS
Feature Highlights:
Product Model |
RG-S5750C-28GT4XS-H |
RG-S5750C-48GT4XS-H |
RG-S5750C-28SFP4XS-H |
RG-S5750C-48SFP4XS-H |
RG-S5750-48GT4XS-HP-H |
|||||
GE RJ45 port |
28 |
48 |
8 (Combo) |
n/a |
48 |
|||||
GE SFP port |
4 (Combo) |
n/a |
28 |
48 |
n/a |
|||||
10GE SFP+ port |
4 |
4 |
4 |
4 |
4 |
|||||
Card slot |
2 |
2 |
2 |
2 |
n/a |
|||||
Card type |
1-port QSFP+ dedicated stack card |
1-port QSFP+ dedicated stack card 4-port 10GE SFP+ interface card |
1-port QSFP+ dedicated stack card |
1-port QSFP+ dedicated stack card |
n/a |
|||||
ETH management port |
1 |
1 |
1 |
1 |
1 |
|||||
Console port (RJ45) |
1 |
1 |
1 |
1 |
1 |
|||||
Console port (Mini USB) |
1 |
1 |
1 |
1 |
1 |
|||||
USB 2.0 port |
1 |
1 |
1 |
1 |
1 |
|||||
Switching capacity |
598Gbps/5.98Tbps |
598Gbps/5.98Tbps |
598Gbps/5.98Tbps |
598Gbps/5.98Tbps |
598Gbps/5.98Tbps |
|||||
Forwarding rate |
222Mpps |
252Mpps |
222Mpps |
252Mpps |
132Mpps |
|||||
MAC table size |
64,000 |
64,000 |
64,000 |
64,000 |
64,000 |
|||||
ARP table size |
20,000 |
20,000 |
20,000 |
20,000 |
20,000 |
|||||
Jumbo frame |
9216 Bytes |
9216 Bytes |
9216 Bytes |
9216 Bytes |
9216 Bytes |
|||||
Packet buffer |
32Mbit |
32Mbit |
32Mbit |
32Mbit |
32Mbit |
|||||
Maximum |
n/a |
1480W |
||||||||
PoE/PoE+ enabled port |
48 |
|||||||||
Standard |
IEEE802.3af/at |
|||||||||
Dimensions(WxDxH) |
440 X 280 X 44mm |
440 X 300 X 44mm |
440 X 300 X 44mm |
440 X 340 X 44mm |
440 X 420 X 44mm |
|||||
Unit weight |
3.9kg |
4.2kg |
4.2kg |
4.7kg |
6.1kg |
|||||
Type |
Hot swappable |
|||||||||
Redundancy |
1+1 |
1+1 |
1+1 |
1+1 |
1+1 |
|||||
AC frequency |
50/60Hz |
|||||||||
Rated AC voltage |
100~240V |
|||||||||
Maximum AC voltage |
90~264V |
|||||||||
Rated HVDC voltage |
240V DC |
|||||||||
Maximum HVDC voltage |
192~288V DC |
|||||||||
Rated DC voltage |
-36V ~ -72V DC |
|||||||||
Maximum power rating |
140W |
140W |
140W |
300W |
2300W |
|||||
Idle power rating |
45W |
45W |
55W |
100W |
70W |
|||||
Dissipation mode |
Air-cooled heat dissipation. Intelligent speed adjustment |
|||||||||
Number of fan |
3 |
3 |
3 |
3 |
3 |
|||||
Airflow |
Air flows in from the left and exhausts from the right |
|||||||||
Safety |
EN 60960-1, IEC 60950-1 |
EN 60960-1 |
||||||||
EMC |
EN 300 386 |
|||||||||
Emissions |
EN 55022, EN55032 |
|||||||||
Immunity generic |
EN 55024 |
|||||||||
ESD |
EN 61000-4-2 |
|||||||||
Radiated |
EN 61000-4-3 |
|||||||||
EFT/Burst |
EN 61000-4-4 |
|||||||||
Surge |
EN 61000-4-5 |
|||||||||
Conducted |
EN 61000-4-6 |
|||||||||
Power frequency magnetic field |
EN 61000-4-8 |
|||||||||
Voltage dips and interruptions |
EN 61000-4-11 |
|||||||||
Harmonics |
EN 61000-3-2 |
|||||||||
Flicker |
EN 61000-3-3 |
|||||||||
Anti-gas corrosion |
GB-T2423.51-2012(Refer to IEC 60068-2-60) |
|||||||||
Operating temperature |
0 ℃ ~ 50 ℃ |
|||||||||
Storage temperature |
-40 ℃ ~ 70 ℃ |
|||||||||
Operating humidity |
10%~90% RH |
|||||||||
Storage humidity |
5%~95% RH |
|||||||||
Operating altitude |
-500 ~ 5000m |
|||||||||
MTBF(hours) |
555960 |
513460 |
506320 |
523510 |
451400 |
|||||
Ethernet |
Full-duplex, Half-duplex, Auto negotiation, Flow control on interface, Jumbo frames, Link aggregation(IEEE802.3ad, LACP, maximum 8 member ports per AP), 2048 maximum aggregation ports, Load balancing, Broadcast storm control |
|||||||||
VLAN |
IEEE802.1Q, 4094 VLAN ID, 4094 VLANIF interface, Access mode, Trunk mode, Default VLAN, Port-based VLAN, MAC-based VLAN, Protocol based VLAN, IP subnet-based VLAN, Voice VLAN, GVRP, Super VLAN, Private VLAN, Guest VLAN |
|||||||||
MAC |
Automatic learning and aging of MAC addresses, Static and dynamic MAC address entries, Interface-based and VLAN-based MAC address learning limiting, Sticky MAC, MAC address spoofing guard |
|||||||||
ARP |
Static ARP, Trusted ARP, Gratuitous ARP, Proxy ARP, Local proxy ARP, ARP trustworthiness detection, ARP-based IP guard |
|||||||||
STP |
STP(IEEE802.1D), RSTP(IEEE802.1w), MSTP(IEEE802.1s), 64 MST instances, Port Fast, BPDU guard, BPDU filter, TC guard, TC filter, Root guard, Auto edge, BPDU transparent transmission, BPDU tunnel, VLAN-Specific Spanning Tree(VSST, working with PVST, PVST+ and RPVST) |
|||||||||
ERPS |
G.8032 v1/v2, Single-ring, Tangent-ring, Intersecting-ring, Load balancing |
|||||||||
L2 multicast |
IGMP v1/v2/v3 snooping, IGMP filter, IGMP fast leave, IGMP querier, IGMP security control, IGMP profile, MLD v1/v2 snooping, MLD filter, MLD fast leave, MLD source check |
|||||||||
QinQ |
Basic QinQ, Selective QinQ(Flexible QinQ), 1:1 VLAN switching, N:1 VLAN switching VLAN mapping, TPID configuration, MAC address replication, L2 transparent transmission, Priority replication, Priority mapping |
|||||||||
IPv4 unicast routing |
IPv4 static routing, RIPv1/v2, OSPFv2, BGP4, MBGP, IS-IS, PBR, VRF, ECMP, WCMP, Routing policies, 12000 IPv4 routing table |
|||||||||
IPv6 unicast routing |
IPv6 static routing, RIPng, OSPFv3, BGP4+, IS-ISv6, PBRv6, VRFv6, Packet–based load balancing and flow-based load balancing, 6000 IPv6 routing table |
|||||||||
IPv6 feature |
ND(Neighbor Discovery), 10000 ND entries, ND snooping, 6 over 4 manual tunnel, 6 to 4 auto tunnel, ISATAP, IPv4 over IPv6 tunnel, IPv6 over IPv6 tunnel, GRE tunnel (4 over 6), GRE tunnel (6 over 6), IPv6 extender option head, Manually configure local address, Automatically create local address, 0-64 bit mask, 65-128 bit mask |
|||||||||
Multicast routing |
IGMPv1/v2/v3, MLDv1/v2, PIM-DM, PIM-SM, PIM-SSM, PIM-DMv6, PIM-SMv6, MSDP, MCE, IGMP proxy, MLD proxy, Multicast static routing, 8000 IPv4 multicast routing table, 4000 IPv6 multicast routing table |
|||||||||
DHCP |
DHCP server/relay/client, DHCPv6 server/relay/client, DHCP option 43/82/138 |
|||||||||
MPLS |
MPLS labels and forwarding, LSP, LDP, Inter-domain LDP LSP |
|||||||||
MPLS L3 VPN |
BGP VPN, IS-IS VPN, OSPF VPN |
|||||||||
BFD |
Single-hop BFD, BFD for IPv4 static routes/OSPF/IS-IS/BGP4/VRRP/MPLS/PBR, BFD for IPv6 static routes/OSPFv3/IS-ISv6/BGP4+/VRRPv6/PBRv6 |
|||||||||
DLDP |
DLDP for IPv4 static routes/OSPF/BGP4/VRRP/PBR |
|||||||||
LLDP |
IEEE802.1AB 2005, ANSI/TIA-1057, LLDP, LLDP-MED, LLDP-PoE |
|||||||||
RLDP |
Uni-directional link detection, Bi-directional forwarding detection, Downlink loop detection |
|||||||||
VSU |
9 VSU(Virtual Switch Unit) stacked members, 80Gbps maximum stacking bandwidth with service port VSL connection, Traffic balancing |
|||||||||
VRRP |
VRRPv3, VRRP+ |
|||||||||
REUP |
REUP(Ruijie Rapid Ethernet Uplink Protection Protocol) for dual uplink backup, VLAN load balancing |
|||||||||
GR |
GR for RIP/OSPF/IS-IS/BGP/MPLS L3 VPN/LDP |
|||||||||
RNS |
RNS test for ICMP/DNS/TCP, Track support for RNS |
|||||||||
Stream classification |
Classification based on IEEE802.1p/DSCP/TOS |
|||||||||
Shaping |
Rate-limit on ingress/egress traffic on interface |
|||||||||
Congestion avoidance |
RED, WRED, Tail drop |
|||||||||
Congestion management |
SP, WRR, DRR, WFQ, SP+WFQ, SP+WRR, SP+DRR, 8 queue priorities per port |
|||||||||
ACL entries |
3500 IPv4/v6 rules |
|||||||||
ACL type |
Standard IP ACL, Extended IP ACL, MAC-extended ACL, Time-based ACL, Expert ACL, ACL80, IPv6 ACL, SVI router ACL, ACL logging, ACL counter, ACL remark, ACL redirection, Security channel, Protected port, Port security |
|||||||||
ARP security |
ARP check, DAI, Trusted ARP, ARP trustworthiness detection, Gateway-targeted ARP spoofing prevention, ARP rate-limit, |
|||||||||
Attack defense |
CPP(CPU Protection Policy), NFPP(Network Foundation Protection Policy) guard for ARP/IP/ICMP/DHCP/DHCPv6/ND/Self-defined attack, URPF |
|||||||||
IP |
IP source guard v4/v6, 3500 IPv4 source guard user capacity, 1500 IPv6 source guard user capacity |
|||||||||
DHCP |
DHCP snooping, DHCPv6 snooping, DHCP snooping on option 82 |
|||||||||
AAA |
Local, RADIUS, RADIUS v6, TACACS+ |
|||||||||
IEEE802.1X |
IEEE802.1X port/MAC based authentication, Dynamic VLAN and ACL assignment, MAC authentication bypass |
|||||||||
Web portal |
Ruijie 1st-Gen and 2nd-Gen portal authentication, Portal authentication/accounting, Portal detection and escape |
|||||||||
Login |
CLI, Console, Telnet, Telnet for IPv6, SSH v1.5/v2.0, SSH for IPv6, SCP, SNMP-based NMS, Web-based UI, Fast deploy(Ruijie Cloud App), Cloud management |
|||||||||
File |
Multiple boot configuration, Multiple firmware |
|||||||||
Network |
Ping(v4/v6), Traceroute(v4/v6), sFlow, SNMPv1/v2c/v3, HTTP, HTTPS, RMON(1,2,3,9), CWMP(TR069), Syslog, MIB, |
|||||||||
Application |
DNS client v4/v6, TFTP Server/Client, TFTP Client v6, FTP Server/Client, FTP Server/Client v6, NTP Server/Client, NTP Server/Client v6, SNTP, EEE(IEEE802.3az), OpenFlow v1.0, OpenFlow v1.3, Hot patch, Z-PoE (Non-stop PoE) |
|||||||||
Mirroring |
Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, SPAN, RSPAN, ERSPAN |
|||||||||
Hardware monitoring |
Power supply monitoring, Fan status and alarm monitoring |
Model |
Description |
RG-S5750C-28GT4XS-H |
28 10/100/1000BASE-T ports, 4 100/1000BASE-X SFP ports (combo), 4 1G/10GBASE-X SFP+ ports, 2 extension slots, 2 modular power slots, required to purchase at least 1 power module |
RG-S5750C-48GT4XS-H |
48 10/100/1000BASE-T ports, 4 1G/10GBASE-X SFP+ ports, 2 extension slots, 2 modular power slots, required to purchase at least 1 power module |
RG-S5750C-28SFP4XS-H |
28 100/1000BASE-X SFP ports, 8 10/100/1000BASE-T ports (combo), 4 1G/10GBASE-X SFP+ ports, 2 extension slots, 2 modular power slots, required to purchase at least 1 power module |
RG-S5750C-48SFP4XS-H |
48 100/1000BASE-X SFP ports, 4 1G/10GBASE-X SFP+ ports, 2 extension slots, 2 modular power slots, required to purchase at least 1 RG-PA150I-F power module |
RG-S5750-48GT4XS-HP-H |
48 10/100/1000BASE-T PoE+ ports, 4 1G/10GBASE-X SFP+ ports, 2 modular power slots, required to purchase at least 1 RG-M5000E-AC500P power module |
Module |
Description |
M5000H-01QXS |
1-port QSFP+ stacking module (stacking module for QSFP+ BASE-X ports, only for stacking between S5750C-H Series) |
M5000H-04XS |
4-port 10GE SFP+ interface module (Only for RG-S5750C-48GT4XS-H and RG-S5750C-48SFP4XS-H models; Only extension Slot-1 of RG-S5750C-48GT4XS-H and RG-S5750C-48SFP4XS-H models supports the module, the extension Slot-2 cannot be used.) |
Power Supply |
Description |
RG-M5000E-AC500P |
AC power module, 500W power budget, max 370W for PoE, for RG-S5750-48GT4XS-HP-H. |
RG-PA1150P-F |
AC power module, 1150W power budget, max 740W for PoE, for RG-S5750-48GT4XS-HP-H |
RG-PA150I-F |
AC power module, 150W power budget, for RG-S5750C-48SFP4XS-H |
RG-PA70I |
AC power module, 70W power budget, for RG-S5750C-28GT4XS-H、RG-S5750C-28SFP4XS-H、RG-S5750C-48GT4XS-H |
RG-PD70I |
DC power module, 70W power budget, for RG-S5750C-28GT4XS-H、RG-S5750C-28SFP4XS-H、RG-S5750C-48GT4XS-H |
Transceiver |
Description |
FE-SFP-LX-MM1310 |
100M multimode interface module (2km) |
FE-SFP-LH15-SM1310 |
100M single-mode interface module (15km) |
Mini-GBIC-GT |
1000BASE-GT mini GBIC transceiver |
Mini-GBIC-SX-MM850 |
1000BASE-SX mini GBIC transceiver (850nm) |
Mini-GBIC-LX-SM1310 |
1000BASE-LX mini GBIC transceiver (1310nm) |
Mini-GBIC-LH40-SM1310 |
1000BASE-LH mini GBIC transceiver (1310nm, 40km) |
Mini-GBIC-ZX50-SM1550 |
1000BASE-ZX mini GBIC transceiver (1550nm, 50km) |
Mini-GBIC-ZX80-SM1550 |
1000BASE-ZX mini GBIC transceiver (1550nm, 80km) |
Mini-GBIC-ZX100-SM1550 |
1000BASE-ZX mini GBIC transceiver (1550nm, 100km) |
XG-SFP-SR-MM850 |
10GBASE-SR, SFP+ transceiver, MM (850nm, 300m, LC) |
XG-SFP-LR-SM1310 |
10GBASE-SR, SFP+ transceiver (1310nm, 10km, LC) |
XG-SFP-ER-SM1550 |
10GBASE-SR, SFP+ transceiver (1550nm, 40km, LC) |
XG-SFP-AOC1M |
10GBASE SFP+ optical stack cable (included both side transceivers) for S2910 and S5750-H Series Switches, 1 meter |
XG-SFP-AOC3M |
10GBASE SFP+ optical stack cable (included both side transceivers) for S2910 and S5750-H Series Switches, 3 meters |
XG-SFP-AOC5M |
10GBASE SFP+ optical stack cable (included both side transceivers) for S2910 and S5750-H Series Switches, 5 meters |
40G-AOC-5M |
40G QSFP+ optical stack cable (included both side transceivers) for S5750-H Series, S6220 Series, S8600E Series and N18000 Series Switches, 5 meters |
40G-QSFP-SR-MM850 |
40G SR fiber module for QSFP+ interface (OM3/OM4 MPO fiber, 8-core, wavelength 850nm, transmission distance is 100m for OM3 fiber and 150m for OM4 fiber) |
40G-QSFP-LR4 SM1310 |
40G LR single-mode fiber module for QSFP+ interface, transmission distance up to 10km (LC fiber is required, 2-core, wavelength 1310nm) |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contattaci
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey